Skywatcher 200PDS 观测站、风扇和后盖
Skywatcher 200PDS Stand, fan and rear cover
使用说明
- 所有模型资源均由用户上传分享,内容来源于网络公开资源
- 侵权投诉:通过抖音私信 @jobsfan 联系我们(需附版权证明),24小时内处理
- 模型将通过邮件发送(5分钟内自动发送),感谢理解带宽压力,超过1小时没收到,请联系我们
关于费用
我们是爱好者共建社区,为维持服务器成本,每个模型收取微量费用(仅覆盖基础开支)。我们承诺最低成本运营,感谢您的支持!
扫码手机访问
抖音私信 @jobsfanSummary
Tapa trasera para Skywatcher 200PDS / Rear cover for Skywatcher 200PDS
Spanish :
He diseñado este conjunto de piezas para la parte posterior de mi skywatcher 1000/200PDs con tres objetivos:
1- Evitar la entrada de luz posterior. Aunque mi experiencia es que no es suficiente ya que sigue entrando algo de luz entre el tubo negro y pìeza blanca original del telescopio por lo que si se desea hay que añadir cinta para cerrar este punto de entrada de luz.
2- Incorporar un ventilador para mejorar la aclimatación térmica del tubo. En este caso he usado un Noctua de 5V por USB para conectarlo a un powerbank o al Asiair plus.
3- Pies robustos para permitir poner el telescopio de pie, protegiendo los tornillos de colimación.
Recomendable imprimir en PETG con bastante densidad de relleno. Yo he usado 40%
La tapa pequeña es opcional y solo tiene el objetivo de mejorar el aislamiento de luz cuando el ventilador no está funcionando
Requiere 3 tornillos M3 para sujetar la pieza exterior a la interior, sin tuercas.
La precisión es importante ya que para asegurar la fijación al telescopio hay que aplicar algo de fuerza, pero debe quedar bien fijado para mayor seguridad
English
I designed this set of parts for the back of my Skywatcher 1000/200PDs for three purposes:
1- To prevent back light from entering. Although my experience is that it is not enough because some light still enters between the black tube and the original white piece of the telescope, so if desired, tape must be added to close this point of light entry.
2- Incorporate a fan to improve the thermal acclimatization of the tube. In this case I used a Noctua 5V by USB to connect to a power bank or the Asiair plus.
3- Stable feet to keep the telescope upright and protect the collimation screws.
It is recommended to print in PETG with enough filling density. I used 40%.
The small cover is optional and only serves to improve light isolation when the fan is not running.
It requires 3 M3 screws to attach the outer part to the inner part, no nuts.
Accuracy is important as some force is required to secure it to the telescope, but it must be securely fastened for safety.
Print Settings
- Printer brand:
Artillery
- Printer:
Artillery Sidewinder X3 Pro
- Rafts:Doesn't Matter
- Supports:No
- Resolution:0.32
- Infill:40
- Filament brand:
SUNLU
- Filament color:
matte black
- Filament material:
PETG
Tags
猜你喜欢
联系我们
热门推荐
-
isobaric 等压型低音喇叭 V1.0 模型2023-03-26
-
地心版怪兽型6x18针孔Gamera2023-03-27
-
业余无线电爱好者 - 线绕装置 / EFHW 统计装置2024-04-10
-
小米智能手环8Pro充电座2024-04-29
-
牛奶盒2024-05-08
最热下载
-
Valorant 杰特的姿态2023-03-26
-
通用型1/10比例底盘 - DKS基础款2023-03-26
-
索尼NP-FW50电池专用外壳(5个装)2024-04-24
-
Neptune 4 / 4 Pro Cura 切片配置文件与使用教程2024-05-02
-
厨房水槽滤网过滤器2025-06-05
最新模型
-
丰田22RE发动机Starer电机2025-08-08
-
3d打印全向自行车(部分金属在文件里面包含CAD图纸)2025-07-25
-
女式凉鞋2025-07-16
-
天使和恶魔2025-07-16
-
坏龙家的大宝贝女生别下2025-06-26